- Product Categories
- Vortex Flowmeter
- Electromagnetic flowmeters
- Turbine Flowmeter
- Orifice Flowmeter
- V-Cone flowmeter
- Oval gear flow meter
- Swirlmeter
- Friendly Links
Information Name: | Shanghai factory specializes in ethanol meter DN50 |
Published: | 2014-12-25 |
Validity: | 365 |
Specifications: | |
Quantity: | 99.00 |
Price Description: | |
Detailed Product Description: | Details KH-LDE ethanol flowmeter: KH-LDE ethanol flowmeter to measure the inner tube is a conductive medium volume flow meter based on Faraday induction law of electromagnetic induction, using embedded microcontroller technology, digital excitation, while the electromagnetic flow count on using the CAN fieldbus, is a national initiative, technology has reached domestic leading level. KH-LDE intelligent electromagnetic flowmeter meet live shows while you can also output 4 ~ 20mA current signal for recording, regulation and control, has been widely used in chemical industry, environmental protection, metallurgy, pharmaceutical, paper, water supply and drainage and other industrial technical and management department. KH-LDE electromagnetic flowmeter to measure flow of conductive liquids in addition, it can also measure the liquid-solid two-phase, high-viscosity fluid and salts, acid and alkali liquid volume flow. Ethanol meter Features: ◆ meter structure is simple, reliable, no moving parts, long working life. ◆ No closure blocking components, there is no pressure loss and fluid clogging. ◆ no mechanical inertia, fast response, good stability, can be used in automatic detection, regulation and program control system. ◆ measurement accuracy is not measured media types and influence temperature, viscosity, density, pressure and other physical parameters. ◆ using different combinations of Teflon or rubber material lining and Hc, Hb, 316L, Ti and other electrode materials can be adapted to the needs of different media. ◆ available pipeline, plug-flow models. ◆ use EEPROM memory, data storage protection measure operational safety and reliability. ◆ have integration and separation of two types. ◆ High-resolution backlit LCD display. Ethanol flowmeter technology parameters: ◆ meter accuracy: Pipeline 0.5, 1.0; plug-in 2.5 ◆ Measurement medium: conductivity is greater than 5μS / various liquid and liquid-solid two-phase flow cm of. ◆ flow rate range: 0.2 ~ 8m / s ◆ Working pressure: 1.6MPa ◆ Ambient temperature: -40 ℃ ~ + 50 ℃ ◆ Medium temperature: ≤180 ℃ Teflon-lined rubber material lining ≤65 ℃ ◆ Explosion-proof mark: ExmibdⅡBT4 ◆ external magnetic interference: ≤400A / m ◆ shell protection: Integrated type: IP65; separate type: Sensor IP68 (5 meters underwater, is limited to the rubber lining) converter IP65 ◆ Output signal: 4 ~ 20mA.DC, load resistance 0 ~ 750Ω ◆ communication output: RS485 or CAN bus ◆ Electrical connection: M20 × 1.5 thread, φ10 cable hole ◆ Power supply voltage: 90 ~ 220V.AC, 24 ± 10% V.DC ◆ Maximum power consumption: ≤10VA ethanol flowmeter Instrument selection: ◆ measuring range to confirm the general industrial use electromagnetic flowmeter measured medium flow rate to 2 ~ 4m / s is appropriate, in exceptional circumstances, the minimum flow rate should not be less than 0.2m / s, the maximum should not exceed 8m / s. If the medium contains solid particles, the flow rate should be less than usual 3m / s, to prevent excessive friction lining and electrode; for viscous fluid, the flow rate can select more than 2m / s, the larger the flow rate on the electrode attachment helps to automatically eliminate the sticky Lag substrates, help improve the measurement accuracy. Q has been determined in the range of conditions, to determine the size of the meter diameter D of the velocity V of the above range, the value is calculated by the following formula: Q = πD2V / 4 Q: flow rate (m / h) D: pipe diameter V : flow rate (m / h) Range Q electromagnetic flowmeter flow should be greater than the maximum expected value, and the normal flow value slightly larger than the 50% full scale of the meter is appropriate. KH-LDE ethanol Flowmeter Selection Table Model Diameter (mm) flow range (m3 / h) Diameter (mm) Diameter (mm) flow range (m3 / h) KH - LDE15 DN15 0.32-6.36 KH --LDE / LCD450 DN450 286.13-5722.65 KH --LDE20 DN20 0.57-11.30 KH --LDE / LCD500 DN500 353.25-7065.00 KH --LDE25 DN25 0.88-17.66 KH --LDE / LCD600 DN600 508.68-10173.60 KH --LDE32 DN32 1.45-28.94 KH --LDE / LCD700 DN700 692.37-13847.40 KH --LDE40 DN40 2.26-45.22 KH --LDE / LCD800 DN800 904.32-18086.40 KH --LDE50 DN50 3.53-70.65 KH --LDE / LCD900 DN900 1144.53-22890.60 KH --LDE65 DN65 5.97-119.40 KH --LDE / LCD1000 DN1000 1413.00-28260.00 KH --LDE80 DN80 9.04-180.86 KH --LDE / LCD1200 DN1200 2034.72-40694.40 KH --LDE100 DN100 14.13-282.60 KH --LDE / LCD1400 DN1400 2769.48-55389.60 KH --LDE125 DN125 22.08-441.56 KH --LDE / LCD1600 DN1600 3617.28-72345.60 KH --LDE150 DN150 31.79-635.85 KH --LDE / LCD1800 DN1800 4578.12-91562.40 KH - LDE / LCD200 DN200 56.52-1130.40 KH --LDE / LCD2000 DN2000 5652.00-113040.00 KH - LDE / LCD250 DN250 88.31-1766.25 KH --LDE / LCD2200 DN2200 6838.92-136778.40 KH - LDE / LCD300 DN300 127.17-2543.40 KH --LDE / LCD2400 DN2400 8138.88-162777.60 KH - LDE / LCD350 DN350 173.09-3461.85 KH --LDE / LCD2600 DN2600 9551.88-191037.60 KH - LDE / LCD400 DN400 226.08-4521.60 Code electrode material K1 316L K2 HB K3 HC K4 K5 titanium, tantalum K6 K7 platinum alloy stainless steel coated tungsten carbide lined Code F4 C2 C1 Teflon material poly FEP F46 C3 polyvinyl fluoride co poly vinyl record FS C4 C5 butadiene rubber polyurethane rubber code Function E1 0.3 级 E2 0.5 级 E3 级 1 F1 4-20Madc, load ≤750Ω F2 0-3khz, 5v active, variable pulse width, output high effective frequency F3 RS485 interface Std T1 T2 T3 high-temperature ultra-high temperature type P1 0.6MPa P2 1.0MPa P3 1.6MPa P4 4.0MPa D1 220VAC ± 10% D2 24VDC ± 10% J1 J2 body structure sub-body structure of a body structure J3 proof product installation diagram: The main advantage of KH-LDE ethanol as a meter) electromagnetic flowmeter sensor structure is simple, with no moving parts inside the measuring tube, and there is no obstacle fluid flow reducing members. So it will not cause any additional pressure loss when the fluid passes through the meter, is one of the lowest energy consumption flow meter flowmeter. 2) Dirty measurable medium, corrosive media and suspension of liquid-solid two-phase flow. This is because the instrument in the measuring pipe unimpeded flow of parts, in contact with the fluid to be measured is measured pipe-lining and the electrode, and its material may be selected according to the nature of the measured fluid. For example, do polytrifluoroethylene or Teflon-lined, measure a variety of acid, alkali, salt and other corrosive media; do wear-resistant rubber lining, it is particularly suitable for measuring with solid particles, wear larger pulp, cement mortar phase fluids with fiber and a variety of liquid and pulp suspension body. 3) electromagnetic flowmeter is a volumetric flow measurement instruments, in the measurement process, it is not measured medium temperature, viscosity, density conductivity (in a certain range) effects. Therefore, the electromagnetic flowmeter calibrated simply with the water, the heart can be used to measure the flow rate of other conductive liquid. 4) output electromagnetic flowmeter and the average velocity is proportional to the measured only medium with the flow state under symmetric distribution (laminar or turbulent) irrelevant. So span a very wide range of the electromagnetic flowmeter, the measurement range of up to 100: 1, and some even up to 1000: 1 flow range can run. 5) electromagnetic flowmeter no mechanical inertia, responsive, you can measure the instantaneous flow pulsation, but also measure the flow of both positive and negative directions. 6) Industrial caliber electromagnetic flowmeter very wide range, from a few millimeters up to several meters, and the country has a diameter up to 3m of actual flow calibration equipment, laid the foundation for the application and development of electromagnetic flowmeter. The main deficiency of ethanol flowmeters that are still present are: a) can not be used to measure gases, vapors and liquids containing a large amount of gas. b) can not be used to measure the conductivity of low liquid medium, such as petroleum products or organic solvents, and other media, the current electromagnetic flowmeter powerless. c) Due to general industrial use electromagnetic flowmeter measuring tube lining material and limitations of electrical insulating materials, can not be used to measure the temperature medium; without the special treatment, it can not be used to measure temperature medium to prevent condensation measuring tube (frost) damage to the insulation. d) electromagnetic flowmeter susceptible to external electromagnetic interference. |
Admin>>>
You are the 55927 visitor
Copyright © GuangDong ICP No. 10089450, Huai An Kehao Automation Instrumentation Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 55927 visitor
Copyright © GuangDong ICP No. 10089450, Huai An Kehao Automation Instrumentation Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility